Loading...
HomeMy WebLinkAboutRESOLUTION - 2-21 - 1/12/2021 - 1000 Busse Road-Small Wireless Facility New Cingular Wireless PCS, AT&TJOHN M. BANKSARCHITECTW I R E L E S S540 W. MADISON ST. 9TH FLOORCHICAGO, IL 60661www.sacw.com312.895.4977A NOKIA COMPANYää604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080JBANKS@WESTCHESTERSERVICES.COM604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080AE@WESTCHESTERSERVICES.COM930 NATIONAL PKWY.SCHAUMBURG, IL 60173OFFICE: 847.592.3000IOT A 001-014586BANKSJOHN M.AEDSNS LICECRHI T E CT SET OFINLIL01 OF 13SITE NAME:CRAN_RCHI_BUFGR_011PACE #:MRCHI041020PTN #:3301AOM32KUSID #:237582FA #:14846200COUNTY:COOKJURISDICTION: ELK GROVE VILLAGEADDRESS:1000 BUSSE RD.ELK GROVE VILLAGE, IL 60007LATITUDE:N 42° 0' 36.49" (42.01013621°)LONGITUDE:W 87° 57' 35.41" (-87.95983519°)SITE ELEV.:649.57' ±3.0' A.M.S.L.PROPERTY OWNER:ELK GROVE VILLAGEPOWER PROVIDER:COMED10 S. DEARBORN STCHICAGO, IL 60661APPLICANT:AT&T MOBILITY930 NATIONAL PARKWAYSCHAUMBURG, IL 60173PROPOSED USE:TELECOMMUNICATIONS FACILITY/SMALL CELLCallbefore you dig.below.Know what'sTO OBTAIN LOCATION OF PARTICIPANTSUNDERGROUND FACILITIES BEFOREYOU DIG IN ILLINOIS, CALL ILLINOIS ONECALLTOLL FREE: 1-800-892-0123 ORwww.illinois1call.comILLINOIS STATUTEREQUIRES MIN OF 2WORKING DAYS NOTICEBEFORE YOU EXCAVATERAT&TPROPOSED SMALL CELL NODESITE NAME:CRAN_RCHI_BUFGR_011PACE ID:MRCHI041020PTN:3301AOM32KUSID:237582FA NUMBER:14846200SITE TYPE:METAL POLESITE ADDRESS:1000 BUSSE RD.ELK GROVE VILLAGE, IL 60007TITLE SHEETSITE LOCATION MAPPROJECT INFORMATIONPROJECT CONSULTANTSAT&T CONSTRUCTION MANAGER:CHRISTINA RACHALPHONE: (312) 887-1085EMAIL: cr630a@att.comAT&T PROJECT MANAGER:VANESSA ROSSPHONE: (217) 814-2314EMAIL: vf2021@att.comSAC SAQ PROJECT MANAGER :SAC WIRELESS540 W. MADISON ST. 9th FLOORCHICAGO, IL 60661CONTACT: ANDREW NOTESTINEEMAIL: andrew.notestine@sacw.comSAC SSD:SAC WIRELESS540 W. MADISON ST. 9th FLOORCHICAGO, IL 60661CONTACT: LISA ALVINEEMAIL: lisa.alvine@sacw.comENGINEER/ARCHITECT:JOHN M. BANKS ARCHITECT604 FOX GLENBARRINGTON, IL 60010CONTACT: JOHN BANKSPHONE: (847) 277-0070EMAIL: JBANKS@WESTCHESTERSERVICES.COMEXISTING POLE ELEVATIONLOCATION MAPSCOPE OF WORKDRAWING INDEXTHE SCOPE OF WORK CONSISTS OF:-EXISTING METAL POLE TO BE REPLACED WITH NEW METAL POLE-INSTALL (1) NEW OMNI ANTENNA 2C4U3MT360X06Fxys0-INSTALL (1) NEW MICRO PCS/AWS 8843 RRU-INSTALL (1) NEW MICRO 700/850 4449 RRU-INSTALL (2) NEW COMMSCOPE RRU MOUNTS & EQUIPMENT FOR PLAN-INSTALL (4) ERICSSON RECTIFIER/PSU AC-08-INSTALL (1) NEW RAYCAP AC DISCONNECT-INSTALL (1) NEW FIBER DEMARC-INSTALL NEW CABLING AS REQUIRED-INSTALL NEW GROUND AS REQUIRED-REPLACE FOUNDATION·CONTRACTOR SHALL FURNISH ALL MATERIAL WITH THE EXCEPTION OFAT&T SUPPLIED MATERIAL.·ALL MATERIAL SHALL BE INSTALLED BY THE CONTRACTOR, UNLESSSTATED OTHERWISE.APPLICABLE BUILDING CODES AND STANDARDSSHEET #SHEET TITLE1TITLE SHEET2OVERALL SITE PLAN3PROPOSED SOUTH & WEST ELEVATION4EQUIPMENT DETAILS5POWER & GROUNDING RISER DIAGRAM6RFDS DETAIL7SIGNAGE DETAILS8GENERAL AND SPECIFIC PROJECT NOTES91011HANDHOLE DETAILSPOLE SPECIFICATIONS & DETAILSAMPHENOL ANTENNA (ADD'L DETAILS) & STEEL POLE MOUNTING DETAILS12STREET LIGHT/TRAFFIC SIGNAL POLE FOUNDATION DETAILS (#818)·2018 INTERNATIONAL RESIDENTIAL CODE·2018 INTERNATIONAL BUILDING CODE·2018 INTERNATIONAL MECHANICAL CODE·2018 INTERNATIONAL PLUMBING CODE·2020 NATIONAL ELECTRICAL CODE·2014 ILLINOIS PLUMBING CODE·2018 INTERNATIONAL FUEL GAS CODE·2018 INTERNATIONAL ENERGY CONSERVATION CODE·2018 INTERNATIONAL PROPERTY MAINTENANCE CODE·2018 INTERNATIONAL FIRE CODE·2018 ILLINOIS ACCESSIBILITY CODESITELAT: 42.01013621°LONG: -87.95983519°13GENERAL AND SPECIFIC PROJECT NOTESNOTE:VILLAGE STREET LIGHT SYSTEMS ARE BASED ON TWO CIRCUITS WITHALTERNATING CIRCUITS POWER EACH LIGHT IN THE STRING. LIGHTSMUST BE TEMPORARILY CONNECTED TO ALLOW OTHER LIGHTS ONTHE CIRCUIT TO OPERATE DURING THE CONSTRUCTION PERIOD. BUS TOP ))))))))))))))))))))))))))))))))) ))))) )))))))))))))))))))))))))))))))))))))))))))) ))))))))))))))H-H H-HH-HH-H H-H JOHN M. BANKSARCHITECTW I R E L E S S540 W. MADISON ST. 9TH FLOORCHICAGO, IL 60661www.sacw.com312.895.4977A NOKIA COMPANYää604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080JBANKS@WESTCHESTERSERVICES.COM604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080AE@WESTCHESTERSERVICES.COM930 NATIONAL PKWY.SCHAUMBURG, IL 60173OFFICE: 847.592.3000IOT A 001-014586BANKSJOHN M.AEDSNS LICECRHI T E CT SET OFINLIL02 OF 13OVERALL SITE PLAN1EXISTING GRADE2" PVC FIBERCONDUIT2NOTE:FIBER INSTALLATIONTO BE PERFORMEDBY OTHERS. JOHN M. BANKSARCHITECTW I R E L E S S540 W. MADISON ST. 9TH FLOORCHICAGO, IL 60661www.sacw.com312.895.4977A NOKIA COMPANYää604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080JBANKS@WESTCHESTERSERVICES.COM604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080AE@WESTCHESTERSERVICES.COM930 NATIONAL PKWY.SCHAUMBURG, IL 60173OFFICE: 847.592.3000IOT A 001-014586BANKSJOHN M.AEDSNS LICECRHI T E CT SET OFINLILPROPOSED EQUIPMENT KEY:··03 OF 13PROPOSED SOUTH& WEST ELEVATIONPROPOSED WIRING KEY:234567819101112131415161712â JOHN M. BANKSARCHITECTW I R E L E S S540 W. MADISON ST. 9TH FLOORCHICAGO, IL 60661www.sacw.com312.895.4977A NOKIA COMPANYää604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080JBANKS@WESTCHESTERSERVICES.COM604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080AE@WESTCHESTERSERVICES.COM930 NATIONAL PKWY.SCHAUMBURG, IL 60173OFFICE: 847.592.3000IOT A 001-014586BANKSJOHN M.AEDSNS LICECRHI T E CT SET OFINLILABC04 OF 13EQUIPMENTDETAILSPROPOSED EQUIPMENT KEY:PROPOSED WIRING KEY:NOTES23456781118642357644/5â2 JOHN M. BANKSARCHITECTW I R E L E S S540 W. MADISON ST. 9TH FLOORCHICAGO, IL 60661www.sacw.com312.895.4977A NOKIA COMPANYää604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080JBANKS@WESTCHESTERSERVICES.COM604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080AE@WESTCHESTERSERVICES.COM930 NATIONAL PKWY.SCHAUMBURG, IL 60173OFFICE: 847.592.3000IOT A 001-014586BANKSJOHN M.AEDSNS LICECRHI T E CT SET OFINLILNOTES:GROUNDING LEGEND:05 OF 13POWER & GROUNDINGRISER DIAGRAMPROPOSED EQUIPMENT KEY:ABCDEFGHPROPOSED WIRING KEY:23456781113161712â2457688 JOHN M. BANKSARCHITECTW I R E L E S S540 W. MADISON ST. 9TH FLOORCHICAGO, IL 60661www.sacw.com312.895.4977A NOKIA COMPANYää604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080JBANKS@WESTCHESTERSERVICES.COM604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080AE@WESTCHESTERSERVICES.COM930 NATIONAL PKWY.SCHAUMBURG, IL 60173OFFICE: 847.592.3000IOT A 001-014586BANKSJOHN M.AEDSNS LICECRHI T E CT SET OFINLIL06 OF 13HANDHOLE DETAILS1 JOHN M. BANKSARCHITECTW I R E L E S S540 W. MADISON ST. 9TH FLOORCHICAGO, IL 60661www.sacw.com312.895.4977A NOKIA COMPANYää604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080JBANKS@WESTCHESTERSERVICES.COM604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080AE@WESTCHESTERSERVICES.COM930 NATIONAL PKWY.SCHAUMBURG, IL 60173OFFICE: 847.592.3000IOT A 001-014586BANKSJOHN M.AEDSNS LICECRHI T E CT SET OFINLIL07 OF 13STREET LIGHT/TRAFFICSIGNAL POLE FOUNDATIONDETAILS (#818)1NOTES: JOHN M. BANKSARCHITECTW I R E L E S S540 W. MADISON ST. 9TH FLOORCHICAGO, IL 60661www.sacw.com312.895.4977A NOKIA COMPANYää604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080JBANKS@WESTCHESTERSERVICES.COM604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080AE@WESTCHESTERSERVICES.COM930 NATIONAL PKWY.SCHAUMBURG, IL 60173OFFICE: 847.592.3000IOT A 001-014586BANKSJOHN M.AEDSNS LICECRHI T E CT SET OFINLIL08 OF 13POLE SPECIFICATIONS& DETAILS1 JOHN M. BANKSARCHITECTW I R E L E S S540 W. MADISON ST. 9TH FLOORCHICAGO, IL 60661www.sacw.com312.895.4977A NOKIA COMPANYää604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080JBANKS@WESTCHESTERSERVICES.COM604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080AE@WESTCHESTERSERVICES.COM930 NATIONAL PKWY.SCHAUMBURG, IL 60173OFFICE: 847.592.3000IOT A 001-014586BANKSJOHN M.AEDSNS LICECRHI T E CT SET OFINLIL09 OF 1312AMPHENOL ANTENNA(ADDITIONAL DETAILS) & STEELPOLE MOUNTING DETAILS JOHN M. BANKSARCHITECTW I R E L E S S540 W. MADISON ST. 9TH FLOORCHICAGO, IL 60661www.sacw.com312.895.4977A NOKIA COMPANYää604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080JBANKS@WESTCHESTERSERVICES.COM604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080AE@WESTCHESTERSERVICES.COM930 NATIONAL PKWY.SCHAUMBURG, IL 60173OFFICE: 847.592.3000IOT A 001-014586BANKSJOHN M.AEDSNS LICECRHI T E CT SET OFINLIL10 OF 13RFDS DETAIL JOHN M. BANKSARCHITECTW I R E L E S S540 W. MADISON ST. 9TH FLOORCHICAGO, IL 60661www.sacw.com312.895.4977A NOKIA COMPANYää604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080JBANKS@WESTCHESTERSERVICES.COM604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080AE@WESTCHESTERSERVICES.COM930 NATIONAL PKWY.SCHAUMBURG, IL 60173OFFICE: 847.592.3000IOT A 001-014586BANKSJOHN M.AEDSNS LICECRHI T E CT SET OFINLIL11 OF 13SIGNAGE DETAILS21345678VINYL DECAL WITH ADHESIVE BACKING.AVAILABLE FROM EXCEL SIGN AND ECAL:PH: (510) 6551-0445VINYL DECAL WITH ADHESIVE BACKING.AVAILABLE FROM EXCEL SIGN AND ECAL:PH: (510) 6551-0445 JOHN M. BANKSARCHITECTW I R E L E S S540 W. MADISON ST. 9TH FLOORCHICAGO, IL 60661www.sacw.com312.895.4977A NOKIA COMPANYää604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080JBANKS@WESTCHESTERSERVICES.COM604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080AE@WESTCHESTERSERVICES.COM930 NATIONAL PKWY.SCHAUMBURG, IL 60173OFFICE: 847.592.3000IOT A 001-014586BANKSJOHN M.AEDSNS LICECRHI T E CT SET OFINLIL12 OF 13GENERAL & SPECIFICPROJECT NOTES1.GROUND TESTED AT 5 OHMS OR LESS.2.5/8" X 10' OR 12' ROD, CAD WELD BELOW GRADE.3.MINIMUM #6 GROUND AND BOND WIRE.4.GROUNDS ROD TO BE PLACED (1) WITHIN NEW POLE FOUNDATION AND (1) WITHIN QUAZITE ENCLOSURE.5.ALL GROUND FASTENERS AND RELATED HARDWARE SHALL BE OF STAINLESS STEEL AND DILECTRIC GREASE SHALL BE USED AT ALLCONNECTIONS. ALL GROUNDING MUST MEET OR EXCEED NESC AND CARRIER STANDARDS.6.UPON COMPLETION OF WORK, CONDUCT CONTINUITY, SHORT CIRCUIT, AND FALL OF POTENTIAL GROUND TESEST FOR APPROVAL. SUBMIT TESTREPORTS TO THE PROJECT MANAGER.GENERAL NOTES:1.THESE NOTES SHALL BE CONSIDERED A PART OF THE WRITTEN SPECIFICATIONS.2.THE WORK SHALL INCLUDE FURNISHING MATERIALS, EQUIPMENT, APPURTENANCES, AND LABOR NECESSARY TO COMPLETE ALL INSTALLATIONS ASINDICATED IN THE CONTRACT DOCUMENTS.3.PRIOR TO THE SUBMISSION OF BIDS, THE CONTRACTOR(S) SHALL VISIT THE JOB SITE(S) AND BE RESPONSIBLE FOR ALL CONTRACT DOCUMENTS,FIELD CONDITIONS AND DIMENSIONS, AND CONFIRMING THAT THE WORK MAY BE ACCOMPLISHED PER THE CONTRACT DOCUMENTS. ANYDISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE IMPLEMENTATION CONSTRUCTION/PROJECT MANAGER ANDENGINEER/CONSTRUCTION/PROJECT MANAGER.4.THE CONTRACTOR SHALL RECEIVE WRITTEN AUTHORIZATION TO PROCEED ON ANY WORK NOT CLEARLY DEFINED OR IDENTIFIED IN THECONSTRUCTION DOCUMENTS BEFORE STARTING ANY WORK.5.ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS, ANDORDINANCES, INCLUDING APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS.6.THE CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS. IF THESERECOMMENDATIONS ARE IN CONFLICT WITH THE CONTRACT DOCUMENTS AND/OR APPLICABLE CODES OR REGULATIONS, REVIEW THE CONFLICTFOR DIRECTIONS WITH THE IMPLEMENTATION CONSTRUCTION/PROJECT MANAGER AND ENGINEER/CONSTRUCTION/PROJECT MANAGER PRIOR TOPROCEEDING.7.THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURESAND FOR COORDINATION OF ALL PORTIONS OF THE WORK UNDER THE CONTRACT INCLUDING CONTACT AND COORDINATION WITH THEIMPLEMENTATION CONSTRUCTION/PROJECT MANAGER AND WITH THE AUTHORIZED REPRESENTATIVE OF ANY OUTSIDE POLE OR PROPERTYOWNER.8.THE CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT EXISTING IMPROVEMENTS, PAVING, CURBS, SIDEWALKS, ADA RAMPS,VEGETATION, GALVANIZED SURFACE OR OTHER EXISTING ELEMENTS AND UPON COMPLETION OF THE WORK, REPAIR ANY DAMAGE THAT OCCUREDDURING CONSTRUCTION TO THE SATISFACTION OF MUNICIPALITY OR PROPERTY OWNER.9.KEEP THE GENERAL AREA CLEAN, HAZARD FREE, AND DISPOSE OF ALL DIRT, DEBRIS, RUBBISH, AND REMOVE EQUIPMENT NOT SPECIFIED ASREMAINING ON THE PROPERTY. LEAVE PREMISES IN CLEAN CONDITION DAILY.10.PLANS ARE INTENDED TO BE DIAGRAMMATIC ONLY AND SHOULD NOT BE SCALED UNLESS OTHERWISE NOTED. RELY ONLY ON ANNOTATEDDIMENSIONS AND REQUEST INFORMATION IF ADDITIONAL DIMENSIONS ARE REQUIRED.11.THE EXISTENCE AND LOCATION OF UTILITIES AND OTHER AGENCY'S FACILITIES ARE OBTAINED BY A SERCH OF AVAILABLE RECORDS. OTHERFACILITIES MAY EXIST BEYOND WHAT IS NOTED. CONTRACTOR SHALL VERIFY LOCATIONS PRIOR TO START OF CONSTRUCTION AND USE EXTREMECARE AND PROTECTIVE MEASURES TO PREVENT DAMAGE TO THESE FACILITIES. CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OFUTILITIES OR OTHER AGENCY'S FACILITIES WITHIN THE LIMITS OF THE WORK, WHETHER THEY ARE IDENTIFIED IN THE CONTRACT DOCUMENTS ORNOT.12.ALL MOUNTS HARDWARE SUCH AS BOLTS, NUTS, LAG CREWS, CLEVIS, CONDUIT STRAPS, STAPLES, (ANYTHING EXPOZED AND CONNECTINGEQUIPMENT TO THE POLE) SHALL BE HOT DIPPED GALVANIZED, UNLESS OTHERWISE STATED. ANY DAMAGE CAUSED TO PAINTED AREAS SHALL BETOUCHED-UP AS REQUIRED.13.THE CONTRACTOR SHALL MAINTAIN AND SUPPLY THE PROJECT MANAGER WITH AS-BUILT PLANS UPON COMPLETIN OF THE PROJECT.1.120/240 POWER OR 120/208 SECONDARY REQUIRED FOR 3-WIRE SERVICE.2.SECONDARY POWER SHALL BE DEPENDANT ON CURRENT AVAILABILITY (@ 3% DROP MIN. 60 AMPS), OR ESTABLISHED BY LOCAL POWER COMPANYDURING ACTUAL POWER WALK.3.POWER ROUTE, WIRE, AND RACEWAY SIZE WILL BE DETERMINED DURING UNDERGROUND OR OVERHEAD ENGINEERING PROCESS.4.GENERAL CONTRACTOR TO REMOVE/CLEAN ALL DEBRIS, NAILS, STAPLES, OR NON-USED VERTICALS OFF THE POLE.5.ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH MUNICIPAL, COUNTY, STATE, AND FEDERAL REGULATIONS.6.CALL JULIE HOTLINE AT (811) 48 HOURS PRIOR TO EXCAVATING.7.ALL LANDSCAPING TO BE RESTORED TO ORIGINAL CONDITION OR BETTER.8.ALL EQUIPMENT TO BE BONDED AS REQUIRED BY LOCAL CODES AND CLIENT REQUIREMENTS.9.ALLOW 3' CLEARANCE AT METERING CABINET DOOR OPENING (IF REQUIRED).ROW POWER CONSTRUCTION NOTES:STANDARD GROUNDING NOTES:STANDARD CONDUIT NOTES:1.PLACE 2" GALVANIZED RIGID OR PVC AS REQUIRED BY LOCAL CODES FOR POWER, GROUND AND FIBER APPLICATIONS.2.ALL CONDUIT WILL BE EQUIPPED WITH 3/8" PULL ROPE OR PULL/MULE TAPE.3.ALL FIBER CONDUIT WILL REQUIRE TRACER WIRE.CARRIER CONSTRUCTION NOTES:1.CONTRACTOR IS TO FOLLOW MOST CURRENT CARRIER NADV/STANDARDS DOCUMENTS PROVIDED TO COMPLETE THIS INSTALLATION.2.CONTRACTOR TO REFER TO THE MOST CURRENT CARRIER NADV FOR APPROVED COAXIAL PROVIDERS AND LINE SWEEP TESTING PROCEDURES.3.CONTRACTOR SHALL INCLUDE AT LEAST ONE "ANRITSU" CERTIFIED LINE SWEEP TECHNICIAN ON SITE DURING ANY CARRIER JOB RELATED TOINSTALLATION OR MAINTENANCE OF COAXIAL CABLE, ANTENNAS. TT-LNA, RF CONNECTORS, JUMPERS, OR DIPLEX FILTERS.4.CONTRACTOR SHALL COMPLETE CARRIER PROVIDED "SMALL CELL SWEEP REPORT" WITH ALL INFORMATION FILLED IN ACCURATELY ANDCOMPLETELY.5.CONTRACTOR TO REFER TO THE MOST CURRENT CARRIER NADV FOR APPROVED "PIM" TEST EQUIPMENT AND GUIDELINES.6.CONTRACTOR IS TO USE BATTERY POWERED "PIM" EQUIPMENT TO VALIDATE THE FINAL LOCATION OF THE COAXIAL JUMPER AND ANTENNA AREFREE OF INTERNAL AND EXTERNAL "PIM" SOURCES.7.CONTRACTOR SHALL PROVIDE AT LEAST ONE TECHNICAL LEAD THAT IS CERTIFIED AND PROFICIENT IN EXECUTING, INTERPRETING, ANDRECORDING "PIM" MEASUREMENTS.8.ALL CABLE AND CABLE EQUIPMENT IDENTIFICATION TAGGING SHALL BE PLASTIC TAGS WITH WAS STRINGS FOR "FIBER" AND "POWER" WITHIN THEQUAZITE ENCLOSURE AND ON THE LIGHT POLE, AND SHALL COMPLY WITH THE LATEST CARRIER STANDARDS.9.THE LOGO PLACARD ON THE COVER OF THE QUAZITE ENCLOSURE SHALL CLEARLY IDENTIFY OWNER. JOHN M. BANKSARCHITECTW I R E L E S S540 W. MADISON ST. 9TH FLOORCHICAGO, IL 60661www.sacw.com312.895.4977A NOKIA COMPANYää604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080JBANKS@WESTCHESTERSERVICES.COM604 FOX GLENBARRINGTON, IL 60010TELEPHONE: 847.277.0070FAX: 847.277.0080AE@WESTCHESTERSERVICES.COM930 NATIONAL PKWY.SCHAUMBURG, IL 60173OFFICE: 847.592.3000IOT A 001-014586BANKSJOHN M.AEDSNS LICECRHI T E CT SET OFINLIL13 OF 13GENERAL & SPECIFICPROJECT NOTESVILLAGE OF ELK GROVE UTILITY PERMIT & VILLAGE NOTES:1.ILLINOIS DEPARTMENT OF TRANSPORTATION CONDITIONS TO BE FOLLOWED.2.INSTALLATION, RESTORATION, TEMPORARY LIGHTING AND CONNECTION OF ELK GROVE VILLAGE LIGHTING TO BE PER ELK GROVE VILLAGE PUBLICWORKS AND LEASE AGREEMENT REQUIREMENTS.GENERAL NOTES:UTILITY PERMIT CONDITIONS & VILLAGE NOTES1.NO WORK SHALL OCCUR UNTIL THE VILLAGE HAS ISSUED A PERMIT AND REQUIRED INSPECTION SHALL BE SCHEDULED 24 HOURS IN ADVANCE. PLEASE CALL 847-357-4220TO SCHEDULE AN INSPECTION. YOUR PERMIT NUMBER WILL BE REQUIRED AT THIS TIME. THE FOLLOWING ITEMS REQUIRE AN INSPECTION:A.ALL CONCRETE FLATWORKB.ALL ASPHALT WORK.C.A FINAL INSPECTION IS REQUIRED FOR ALL PERMITS.2.ALL UTILITIES SHALL BE INSTALLED BY DIRECTION DRILLING METHOD. NO TRENCHING PERMITTED.3.ALL DAMAGED PARKWAY LAWN AND UTILITY EASEMENT AREAS SHALL BE RESTORED WITH 4” OF TOPSOIL AND SOD.4.PRIOR TO, AND IMMEDIATELY AFTER DIRECTIONAL DRILLING THE CONTRACTOR SHALL MEET WITH THE ELK GROVE VILLAGE PUBLIC WORKS DEPARTMENT (847-734-8800)ON-SITE TO VERIFY STREET LIGHTS ARE FUNCTIONING PROPERLY.5.UTILITIES SHALL BE PLACED A MINIMUM OF 30” BELOW THE SURFACE WITHIN THE RIGHT-OF-WAY AND 24” ON PRIVATE PROPERTY OR WITHIN THE PUBLIC UTILITYEASEMENTS.6.UTILITIES ARE NOT PERMITTED TO BE IN INSTALLED BELOW THE ROADWAY EXCEPT WHERE CROSSING A ROADWAY.7.UTILITIES SHALL BE PLACED A MINIMUM OF 5’ HORIZONTALLY AWAY FROM ALL VILLAGE WATER MAIN, STORM SEWER, OR SANITARY SEWER, AND 3’ HORIZONTALLY AWAYFROM VILLAGE ELECTRIC.8.NO “POTHOLING” OR OPEN CUTTING OF ANY PAVEMENT ALLOWED WITHOUT PRIOR APPROVAL BY THE VILLAGE.9.SNOW FENCE OR TYPE 1 BARRICADES SHALL BE REQUIRED AROUND ALL OPEN EXCAVATIONS. PLASTIC SAFETY TAPE IS NOT APPROVED FOR USE AROUND OPENEXCAVATIONS.10.THE MAXIMUM ALLOWABLE HANDHOLE SIZE WITHIN RESIDENTIAL AREAS IS 17” X 24”, OUTSIDE OF RESIDENTIAL AREAS IS 24” X 36” AT GRADE. (CHANNEL SHUTTER BOXSERIES SGLB 2436 OR APPROVED EQUAL).11.THE MAXIMUM ALLOWABLE MANHOLE / VAULT FRAME AND LID DIAMETER IS 26”.12.UTILITIES MARKERS ARE NOT ALLOWED IN THE VILLAGE OF ELK GROVE.13.EXISTING LUMINAIRE MUST BE SALVAGED AND RETURNED TO THE VILLAGE OF ELK GROVE VILLAGE.14.NOTICE SHALL BE PROVIDED TO THE VILLAGE PRIOR TO THE START OF CONSTRUCTION.NOTE:TO CONFIRM THE COLOR, SEND OVER PHOTOS OF A FEW COLOR OPTIONS HELD UP AGAINST THE EXISTING POLE.EGAAIEGAAI0POLE NUMBER DETAIL: